View Basket
0 items 0.00

If your country is not listed below, please visit MalvernPanalytical.com for details of the sales contact in your country.

Americas

Europe

Optics

View As :

or Register to view prices and add items to your basket

Showing 1 to 10 of 11 products

SMALL ANGLE SCATTER SLIT

Product Number : 9430 030 83601

Incident fixed slit for incident beam optic such as mirror, hybrid or focusing mirror to limit the size of the incident beam for small angle scattering experiments

or Register to view prices and add items to your basket

Compatible with: Empyrean | X'Pert 3, Powder, PRO MPD

BRAGG-BRENTANO HD CU

Product Number : 9430 030 83903

Incident beam optic setting new standard for high quality powder diffraction data, fir use with Cu radiation.

or Register to view prices and add items to your basket

Compatible with: Empyrean | X'Pert 3, Powder, PRO MPD | CubiX 3, PRO

SOLLER SLIT 0.01 RAD

Product Number : 9430 030 85101

Soller slit 0.01 radians. For incident and diffracted beam. Exchangeable with Soller slit 0.02 radians (9430 030 85201), 0.04 radians (9430 030 85401) or 0.08 radians (9430 030 85801). A shutter actuator is included. Recommended for the highest angular resolution at low 2Theta angles.

or Register to view prices and add items to your basket

Compatible with: Empyrean | X'Pert 3, Powder, PRO MPD | CubiX 3, PRO | Aeris

SOLLER SLIT 0.02 RAD

Product Number : 9430 030 85201

Soller slit 0.02 radians for incident and diffracted beam optics. Exchangeable with Soller slit 0.01 radians (9430 030 85101), 0.04 radians (9430 030 85401) or 0.08 radians (9430 030 85801). Reduce peak asymmetry at low angles.

or Register to view prices and add items to your basket

Compatible with: Empyrean | X'Pert 3, Powder, PRO MPD | CubiX 3, PRO | Aeris

BETA FILTER NI

Product Number : 9430 031 51031

Ni filter for suppression of unwanted radiation, such as white radiation and Cu K-Beta radiation. Small beta filter, to be used with Cu X-ray tubes.

or Register to view prices and add items to your basket

Compatible with: Empyrean | X'Pert 3, Powder, PRO MPD | CubiX 3, PRO | Aeris

FOCUS.MIRROR MPD CU PFX

Product Number : 9430 031 52631

Incident beam PreFIX module with elliptical X-ray mirror for Cu radiation. The multi-layer crystal converts a divergent beam projected by a line focus of an X-ray tube into a quasi-monochromatic and focused beam of high intensity. White radiation and K-beta lines are virtually eliminated. With a focal point at the detector, the elliptical mirror is ideal for transmission experiments through capillaries, films, foils, and low average atomic number materials, such as pharmaceutical tablets. For EMPYREAN/X’Pert-PRO MPD systems with a goniometer radius of 240 mm. Includes 3 filters; 1 Cu foil (0.1 mm), 1 combined Cu (0.2 mm)/Ni (0.02 mm) foil and 1 Ni foil (0.02 mm)) and a 1/2º divergence slit.

or Register to view prices and add items to your basket

Compatible with: Empyrean | X'Pert 3, Powder, PRO MPD

MICROBEAM MASKS PRIM

Product Number : 9430 061 20001

Set of primary microbeam masks for the X-ray focusing mirrors (Co and Cu) and the X-ray parallel beam mirrors (Co and Cu). It contains three masks of different widths, 0.2 mm, 0.3 mm and 0.5 mm. The primary masks are inserted in the X-ray mirror, close to the X-ray focus. They can be used in combination with either the 9430 061 21001 Microbeam collimators or with the 9430 061 20011 secondary microbeam masks in order to create an intense microbeam with small divergence on the sample.

or Register to view prices and add items to your basket

Compatible with: Empyrean | X'Pert 3, Powder, PRO MPD

MICROBEAM COLLIMATORS

Product Number : 9430 061 21001

Set of microbeam collimators for X-ray focusing and parallel beam mirrors (Co and Cu). Three microbeam collimators are included with different openings, 0..1 mm, 0.3 mm and 0.5 mm. Combination of one microbeam collimator with one of the microbeam primary masks (9430 061 20001) inserted in the X-ray mirror create an intense microbeam with small divergence on the sample.

or Register to view prices and add items to your basket

Compatible with: Empyrean | X'Pert 3, Powder, PRO MPD

PARAL MIRROR INTERF COLL

Product Number : 9430 061 22001

Mechanical interface allowing the microbeam collimators to be mounted on a parallel beam X-ray mirror (Cu or Co). The collimators are magnetically attached to the interface in a very convenient and reproducible way.

or Register to view prices and add items to your basket

Compatible with: Empyrean | X'Pert 3, Powder, PRO MPD

FOC MIRROR INTERF COLL

Product Number : 9430 061 22011

Mechanical interface allowing the microbeam collimators to be mounted on a focusing X-ray mirror (Cu or Co). The collimators are magnetically attached to the interface in a very convenient and reproducible way.

or Register to view prices and add items to your basket

Compatible with: Empyrean | X'Pert 3, Powder, PRO MPD