PRO-TRACE LTU WIN
Compatible with: Floorstanding XRF | Zetium | Axios | Magix (PRO) | Axios Max
Compatible with: Floorstanding XRF | Zetium | Axios | Magix (PRO) | Axios Max
Compatible with: Floorstanding XRF | Zetium
Compatible with: Floorstanding XRF | Zetium
Compatible with: Floorstanding XRF | Zetium
Compatible with: Floorstanding XRF | Zetium
A single calibration program, set up with the Omnian setup samples, is used to quantify the complete composition of almost any type of material. Important functions include an accurate Peak Search <(>&<)> Match algorithm, an advanced Fundamental Parameter algorithm that corrects for the Fluorescent Volume Geometry (FVG) and the unmeasured 'Dark Matrix' compounds, and Adaptive Sample Characterization (ASC) to correct for sample-specific effects.
Compatible with: Zetium | Axios (mAX, 1kW)
Set of 4 standards and one blank (2 replicates of each standard/blank) for analysis of toxic elements in polymers covering the following elements and concentration ranges: · Cr (0 to 24.8 ppm) · Cd (0 to 24.8 ppm) · Hg (0 to 5.3 ppm) · Pb (0 to 22.3 ppm) · As (0 to 0 to 6.4 ppm) · Ni (0 to 10.6 ppm) · Cu ( 0 to 25.1 ppm) · Zn (0 to 5.1 ppm) · Ba ( 0 to 600.7 ppm) · Br (0 to 163.3 ppm)
Compatible with: Zetium | Axios (mAX, 1kW) | Magix (PRO) | Epsilon 4 | PW24XX | PW26XX
Set of 4 standards and one blank (2 replicates of each standard/blank) for analysis of additive elements in polymers. The standards contain certified concentrations of additive elements: · F (0-266ppm) · Na (0-189ppm) · Mg (0-561ppm) · Al (0-385ppm) · Si (0-778ppm) · P (0-94ppm) · S (0-98ppm) · Ca (0-200ppm) · Ti (0-112ppm) · Zn (0-198ppm)
Compatible with: Zetium | Axios (mAX, 1kW) | Magix (PRO) | Epsilon 4 | PW24XX | PW26XX
The ROHS calibration standards in polyethylene designed for meeting the compliance requirements of the ROHS/WEEE and ELV as similar regulations. The set consists of 4 standard disks and one blank. The set comes with 2 replicates of each standard to asset in meeting infinite thickness requirements as well as providing additional standards in case some wear out due to normal use. The standards not only cover the main restricted elements of Br, Cd, Pb, Cr and Hg, but also contain commonly monitored elements such as As, Cl, S, Sb, Sn and Zn. The concentration ranges of the set are as follows: As(0-145ppm),Br(0-980ppm), Cl(0-1075ppm), Cd(0-252ppm), S(0-590ppm), Pb(0-1033ppm), Cr(0-973ppm), Sb(0-345ppm), Hg(0-483ppm), Sn(0-178ppm), Zn(0-976ppm).
Compatible with: Zetium | Axios (mAX, 1kW) | Magix (PRO) | Epsilon 4 | PW24XX | PW26XX
Drift monitor sample (40mm) for Omnian required for maintenance of the Omnian set-up. Note that this monitor sample is also included in the Omnian standards set.
Compatible with: Zetium | Axios Fast | Axios (mAX, 1kW) | Epsilon 4