FENTE SAXS
Incident fixed slit for incident beam optic such as mirror, hybrid or focusing mirror to limit the size of the incident beam for small angle scattering experiments
Compatible avec: Empyrean | X'Pert 3, Powder, PRO MPD
Incident fixed slit for incident beam optic such as mirror, hybrid or focusing mirror to limit the size of the incident beam for small angle scattering experiments
Compatible avec: Empyrean | X'Pert 3, Powder, PRO MPD
Incident beam optic setting new standard for high quality powder diffraction data, fir use with Cu radiation.
Compatible avec: Empyrean | X'Pert 3, Powder, PRO MPD | CubiX 3, PRO
Soller slit 0.01 radians. For incident and diffracted beam. Exchangeable with Soller slit 0.02 radians (9430 030 85201), 0.04 radians (9430 030 85401) or 0.08 radians (9430 030 85801). A shutter actuator is included. Recommended for the highest angular resolution at low 2Theta angles.
Compatible avec: Empyrean | X'Pert 3, Powder, PRO MPD | CubiX 3, PRO | Aeris
Soller slit 0.02 radians for incident and diffracted beam optics. Exchangeable with Soller slit 0.01 radians (9430 030 85101), 0.04 radians (9430 030 85401) or 0.08 radians (9430 030 85801). Reduce peak asymmetry at low angles.
Compatible avec: Empyrean | X'Pert 3, Powder, PRO MPD | CubiX 3, PRO | Aeris
Incident beam PreFIX module with elliptical X-ray mirror for Cu radiation. The multi-layer crystal converts a divergent beam projected by a line focus of an X-ray tube into a quasi-monochromatic and focused beam of high intensity. White radiation and K-beta lines are virtually eliminated. With a focal point at the detector, the elliptical mirror is ideal for transmission experiments through capillaries, films, foils, and low average atomic number materials, such as pharmaceutical tablets. For EMPYREAN/X’Pert-PRO MPD systems with a goniometer radius of 240 mm. Includes 3 filters; 1 Cu foil (0.1 mm), 1 combined Cu (0.2 mm)/Ni (0.02 mm) foil and 1 Ni foil (0.02 mm)) and a 1/2º divergence slit.
Compatible avec: Empyrean | X'Pert 3, Powder, PRO MPD
Set of primary microbeam masks for the X-ray focusing mirrors (Co and Cu) and the X-ray parallel beam mirrors (Co and Cu). It contains three masks of different widths, 0.2 mm, 0.3 mm and 0.5 mm. The primary masks are inserted in the X-ray mirror, close to the X-ray focus. They can be used in combination with either the 9430 061 21001 Microbeam collimators or with the 9430 061 20011 secondary microbeam masks in order to create an intense microbeam with small divergence on the sample.
Compatible avec: Empyrean | X'Pert 3, Powder, PRO MPD
Set of microbeam collimators for X-ray focusing and parallel beam mirrors (Co and Cu). Three microbeam collimators are included with different openings, 0..1 mm, 0.3 mm and 0.5 mm. Combination of one microbeam collimator with one of the microbeam primary masks (9430 061 20001) inserted in the X-ray mirror create an intense microbeam with small divergence on the sample.
Compatible avec: Empyrean | X'Pert 3, Powder, PRO MPD
Mechanical interface allowing the microbeam collimators to be mounted on a parallel beam X-ray mirror (Cu or Co). The collimators are magnetically attached to the interface in a very convenient and reproducible way.
Compatible avec: Empyrean | X'Pert 3, Powder, PRO MPD
Mechanical interface allowing the microbeam collimators to be mounted on a focusing X-ray mirror (Cu or Co). The collimators are magnetically attached to the interface in a very convenient and reproducible way.
Compatible avec: Empyrean | X'Pert 3, Powder, PRO MPD
The Alignment camera with Data Collector camera plug-in allows users to easily align their samples to the point of interest. Images of the point of interest can be saved to the hard drive.
Compatible avec: Empyrean | X'Pert 3, Powder, PRO MPD